IAHR, founded in 1935, is a worldwide independent member-based organisation of engineers and water specialists working in fields related to the hydro-environmental sciences and their practical application. Activities range from river and maritime hydraulics to water resources development and eco-hydraulics, through to ice engineering, hydroinformatics, and hydraulic machinery.
Log On
About IAHRDirectoryCommitteesMy IAHRNews & JournalseLibraryeShopEventsJoin IAHRWorld CongressDonate
spacer.gif
spacer.gif eLibrary
spacer.gif eLibrary
You are here : eLibrary : IAHR World Congress Proceedings : 36th Congress - The Hague (2015) ALL CONTENT : Special sessions : Comparison of physical hydraulic and cfd model measurements of velocity and swirl angle in pump inta...
Comparison of physical hydraulic and cfd model measurements of velocity and swirl angle in pump intakes
Author : JOSEPH ORLINS(1), ZACHARY TAYLOR(2), JUSTN ARNOLD(3)
ABSTRACT
There is a desire within the industry to apply Computational Fluid Dynamics (CFD) models to pump intakes. In an effort to demonstrate the use of CFD for evaluating acceptance of pump intakes, measurements for two conditions in a physical model of a wet pit pumping station are compared to results from a CFD study of the same pump intake.
Quantitative measures of axial and tangential velocities and swirl angles were made in the physical hydraulic model using a 2-D laser Doppler velocimeter (2-D LDV) and traditional swirl meters. The LDV measurements were made at 24 discrete locations at the plane of the pump impeller. The results are compared with those obtained from a steady state CFD model using measurements from 360, 24, and 8 locations.
There is general agreement between the physical model and CFD results for axial flow velocities, both in magnitude and spatial distribution. There is poor correlation between the average swirl angles computed from the CFD and those obtained from the physical model using either the swirl angles computed from the discrete 2-D LDV measurements or the traditional swirl meter.
These results indicate that additional research is needed to develop application guidelines and acceptance criteria for use of CFD models in evaluating flow entering pump inlets.
File Size : 314,212 bytes
File Type : Adobe Acrobat Document
Chapter : IAHR World Congress Proceedings
Category : 36th Congress - The Hague (2015) ALL CONTENT
Article : Special sessions
Date Published : 19/08/2015
Download Now