IAHR, founded in 1935, is a worldwide independent member-based organisation of engineers and water specialists working in fields related to the hydro-environmental sciences and their practical application. Activities range from river and maritime hydraulics to water resources development and eco-hydraulics, through to ice engineering, hydroinformatics, and hydraulic machinery.
Log On
About IAHRDirectoryCommitteesMy IAHRNews & JournalseLibraryeShopEventsJoin IAHRWorld CongressDonate
spacer.gif
spacer.gif eLibrary
spacer.gif eLibrary
You are here : eLibrary : IAHR World Congress Proceedings : 35th IAHR Congress - Chengdu (2013) : THEME 4 - HYDRO-ENVIRONMENT : Improving the Hydraulic Performance of Sediment Retention Ponds: Alternative Inlet and Outlet Design...
Improving the Hydraulic Performance of Sediment Retention Ponds: Alternative Inlet and Outlet Design and Baffles
Author : Arash Farjood , Bruce W. Melville, Asaad Y. Shamseldin and NickVigar
This study addresses the effect of different inlet and outlet configurationsand the influence of baffles on the hydraulic performance of a model pond. The physical model is a trapezoidal pond with top dimensions of 4.1 1.6 m 0.3 m deep and side and end slopes of 2:1. For simulating the sediment forebay, the inlet pipe fills a rectangular tank of 0.3 1.6 0.2 m. For dewatering the pond, three perforated T-bars are fixed to an outlet riser to simulate a floating decant dewatering system. Tracer experiments were carried out using Rhodamine-WT fluorescent dye to obtain residence time distribution (RTD) curves and subsequently assess the hydraulic efficiency. Solid and partial-width baffles were also investigated for their influence on the hydraulic efficiency of the system. Compared with the conventional point inlet and outlet system, the results herein showed that distributing the inflow over the entire width of the pond could successfully improve the hydraulic efficiency, albeit with short circuiting along the sloping side walls. Monitoring the dye aided recognition of preferential flow paths which were subsequently removed by modifying the inlet. On the other hand, the outlet span was adjusted to boost the residence times. Hydraulic efficiencies of about 0.50 compared with 0.18 for the conventional system, illustrated the effectiveness of these configurations. Furthermore, both types of the tested baffles significantly lifted the hydraulic performance giving the highest hydraulic indices of all the tested cases.These results indicated the need for experimental investigation of such systems for an improved understanding of their hydraulic performance.
File Size : 1,285,664 bytes
File Type : Adobe Acrobat Document
Chapter : IAHR World Congress Proceedings
Category : 35th IAHR Congress - Chengdu (2013)
Article : THEME 4 - HYDRO-ENVIRONMENT
Date Published : 18/07/2016
Download Now