IAHR, founded in 1935, is a worldwide independent member-based organisation of engineers and water specialists working in fields related to the hydro-environmental sciences and their practical application. Activities range from river and maritime hydraulics to water resources development and eco-hydraulics, through to ice engineering, hydroinformatics, and hydraulic machinery.
Log On
About IAHRDirectoryCommitteesMy IAHRNews & JournalseLibraryeShopEventsJoin IAHRWorld CongressDonate
spacer.gif
spacer.gif eLibrary
spacer.gif eLibrary
You are here : eLibrary : IAHR World Congress Proceedings : 32nd Congress - Venice (2007) : THEME B: Data Acquisition and Processing For Scientific Knowledge and Public Awareness. : Complexity and catchment modelling systems
Complexity and catchment modelling systems
Author : James E Ball, Kyung-sook Choi
In general, the calibration process involves minimisation of the deviation between recorded information and the simulation predictions through repeated adjustment of control parameters. Implementation of this process requires temporal and spatial information at an adequate resolution to achieve robust predictions from a catchment modelling system. Unfortunately, the available information usually is not adequate for this purpose and it becomes necessary to either use catchment average values or to use other techniques to infer the necessary information. Developments in information technology and the availability of digital information have facilitated the later approach (see, for example, Choi and Ball, 1999). Using the Centennial Park Catchment in Sydney, Australia as a test catchment, inference models for estimation of the control parameters necessary to implement the Stormwater Management Model were developed. A number of alternative inference models were developed to assess the influence of inference model complexity and structure on the calibration of the catchment modelling system. These inference models varied from the assumption of a spatially invariant value (catchment average) to spatially variable with each subcatchment having its own unique values. Furthermore, the influence of different measures of deviation between the monitored information and simulation predictions were considered. Presented herein will be the results of these investigations into the complexity and structure of models used in the calibration process.
File Size : 915,286 bytes
File Type : Adobe Acrobat Document
Chapter : IAHR World Congress Proceedings
Category : 32nd Congress - Venice (2007)
Article : THEME B: Data Acquisition and Processing For Scientific Knowledge and Public Awareness.
Date Published : 01/07/2007
Download Now