DONATE

IAHR Document Library


« Back to Library Homepage « Proceedings of the 41st IAHR World Congress (Singapore, 2025...

Preventing Overflow Instabilities on Half-Round Circular Weirs - an Innovative and Simple Approach

Author(s): Hubert Chanson

Linked Author(s): CN-6046

Keywords: Hydraulic structures; Half-round circular weirs; Nappe instabilities; Ventilation; Splitters; Physical modelling

Abstract: In the last decade, a couple of physical studies highlighted the occurrence of instabilities and non-linear rating rating curve with half-round circular crested weirs, in absence of ventilation. The author conducted a series of physical measurements with half-round circular-crested weirs. Nappe ventilation was provided with various sidewall splitter arrangements. The rectangular splitters induced some flow separation and provided the necessary space for the ventilation of the overflowing nappe with the formation of a stable air cavity underneath. A systematic quantitative comparison between un-ventilated and ventilated circular weirs showed little hysteresis and no overflow instability in presence of ventilation by sidewall splitters. The relationship between water discharge and head above crest was very stable. The results were qualitatively and quantitatively very close, hinting limited effect of the relative splitter size, within the experimental configurations tested herein.

DOI: https://doi.org/10.64697/978-90-835589-7-4_41WC-P1965-cd

Year: 2025

Copyright © 2025 International Association for Hydro-Environment Engineering and Research. All rights reserved. | Terms and Conditions