Author(s): J. W. Li; X. R. Liu
Linked Author(s):
Keywords: Pressure fluctuation; Pump-turbine; Transfer characteristics; Prototype test
Abstract: Considering unit 3 in Zhanghewan pumped storage power station as the research object, transfer characteristics of pressure fluctuation at the vaneless area were studied from the dominant frequencies, the fractional amplitude and the fractional phase at four different measuring points. It was revealed that the variation trends of pressure fractional amplitude (50 Hz and 100 Hz) versus output agreed well at the four points, and the phase difference between the four points varied very small with increasing of output under different water heads. This research could provide instructive inspiration for solving the vibration problems in pumped storage power station, and provide useful thinking for optimizing hydraulic design of the pump-turbine.
DOI: https://doi.org/10.1088/1755-1315/627/1/012001
Year: 2019