DONATE

IAHR Document Library


« Back to Library Homepage « Proceedings of the 25th IAHR Symposium on Hydraulic Machiner...

The Comparative Analysis of Model and Prototype Test Results of Bulb Turbine

Author(s): M Benisek; I Bozic; B Ignjatovic

Linked Author(s):

Keywords: Bulb turbine; Oblique water inflow; Model testing; Prototype testing; Swirl flow

Abstract: This paper presents the problem of the hydropower plant oblique water inflow and its influence on the turbines operation. Oblique water inflow on the low head hydropower plant with bulb turbines influences turbine characteristics. The characteristics change occurs due to swirl incidence in the turbine inlet which spreads to the guide vanes inlet. Downstream, the flow conditions change is caused in the turbine runner in relation to the flow conditions without swirl inflow. Special attention is paid to the phenomenon of swirl flow incidence in the turbine conduit. With the aim of presenting and analyzing the oblique water inflow consequences on the hydropower plant operation, the existing turbine model tests results, performed in the laboratories, and the in situ prototype testing results have been used.

DOI: https://doi.org/10.1088/1755-1315/12/1/012091

Year: 2010

Copyright © 2026 International Association for Hydro-Environment Engineering and Research. All rights reserved. | Terms and Conditions