Clicking "Download" will only navigate to the article page. To access the full article or download the PDF using your institute or individual membership, please click here for detailed instructions.
Author(s): R. Sakthivadivel; S. Thiruvengadachari
Linked Author(s):
Keywords:
Abstract: The seepage characteristics of foundations with a downstream crack is analysed using conformal transformation technique. Two cases are investigated: a downstream vertical crack in a finite depth of pervious stratum and a downstream inclined crack of finite depth in a pervious stratum of infinite depth. Experimental verification of the flow lines with an electrolytic tank model shows satisfactory agreement with the theory. It is shown that a downstream foundation crack, irrespective of its length and inclination, has negligible effect on the seepage characteristics when the crack is at a distance equal to or greater than the depth of the pervious stratum from the downstream end of the hydraulic structure.
DOI: https://doi.org/10.1080/00221687509499720
Year: 1975